您好,欢迎进入上海泰特石油设备科技/服务有限公司官网!

Gas Point

  • GasPointH2S,CO,NH3,HCN,NO2,SO2,O2,Cl2Combustibles(Catalytic0-100%LEL)orCombustibles(IR0-100%LEL)GasTransmitterwithInternalAlarmRelayswww.gasmonitors.come-mail:info@gasmonitors.comOrderingInformationGP-WDGasTransmitterwithCombustibleCatalyticSensorGP-IR-WD

详情介绍

Gas Point

H2S, CO, NH3, HCN, NO2, SO2, O2, Cl2
Combustibles (Catalytic 0-100% LEL) or
Combustibles (IR 0-100% LEL)
Gas Transmitter with Internal Alarm Relays
www.gasmonitors.com
e-mail: info@gasmonitors.com
Ordering Information
GP-WD Gas Transmitter with Combustible Catalytic Sensor
GP-IR-WD Gas Transmitter with Combustible Infrared Sensor
GP-HD Gas Transmitter with H2S Sensor
GP-MD Gas Transmitter with CO Sensor
GP-AD Gas Transmitter with NH3 Sensor
GP-ZD Gas Transmitter with HCN Sensor
GP-DD Gas Transmitter with NO2 Sensor
GP-SD Gas Transmitter with SO2 Sensor
GP-XD Gas Transmitter with O2 Sensor
GP-CD Gas Transmitter with Cl2 Sensor
Accessories and Spares
GP-POWER1 120-240 VAC Power Supply
GP-MBUS4 2-wire/4-wire MODBUS Communication Expansion Module
GP-SEP Sensor Separation Kit
GP-1 Gas Transmitter
GP-SSPB Stainless Steel Process Baffl e
GP-SSCAL4 Stainless Steel GasPoint Splash Guard
GP-DUC-K1 Duct Mount Adaptor
Replacement Sensor Assemblies
SS-RH02.....H2S SS-RM02.....CO SS-RA02.....NH3
SS-RZ02.....HCN SS-RD02.....NO2 SS-RC02.....Cl2
SS-RS02.....SO2 SS-RX02.....O2
SS-RW02....Combustible Catalytic Sensor Assembly
IR-RW03.....Combustible IR Sensor Assembly
FEATURES: Fixed Gas Monitoring Systems
The GasPoint transmitter provides a 4-20 mA output signal that can be
connected to any control system (DCS, PLC, etc.). With advanced sensor
technology and microcontroller based operation, the GasPoint provides
continuous monitoring of hazardous gases.
The GasPoint transmitter can accept any GasPoint sensor type:
electrochemical, catalytic or IR (infrared). All plug-in sensor assemblies
are fi eld-interchangeable.
Full function sensor integrity test (auto) continuously advises gas
sensing ability and life ended
Non-intrusive, one-person calibration with auto zero and
auto span
Equipped with three 5-amp relay contacts—two gas alarm relays
(low/high) and fault alarm. Field-selectable normally energized/
de-energized and latching/non-latching alarm relay functions.
Two backlit alphanumeric LCDs advise all environmental and gas
hazard conditions as well as instrument and sensor status
Remote toxic/oxygen sensors can be installed over 3,900 ft./ 1,100 m
away; combustible sensors over 1,550 ft./475 m.
Kit can be installed at any time.
Alarm setpoints displayed on demand—simply press the
external button
Field programmable alarm levels
Backlight (auto) in low light conditions and alarm
Extensive fault diagnostics
2-way digital communication using MODBUS module
n
One Transmitter
with interchangeable
electrochemical, infrared
and catalytic plug-in sensorsGasPoint
LEL, H2S, CO, NH3, HCN,
NO2, SO2, Cl2 or O2
4-20 mA Gas Transmitter
Display advises: