RIG RAT III 多点无线气体探测系统 独立解决方案 坚固的 Rig Rat III 气体探测系统可提供有毒气体、可燃气体和氧气的多点监测。自供电源和可利用太阳能, Rig Rat III 具有无与伦比的多功能类型,配有广泛的现场配置。具备实时、双向数据传送和遥控传感能力,Rig Rat III 代表了独立气体探测系统的新一代技术水平。 自成一体、本质安全 Rig Rat III 是独立系统的理想选择。 Rig Rat III 完全模块化设计,所有系统元件和现场通讯采用插接接口,如: 远程传感器,远程报警、继电器、太阳能等。微处理器和先进的传感技术保障了可靠性和性能。 | ![]() |
报警状态 大 LCD 显示不断提醒气体的危险。智能 LCD 提供即时诊断信息。 报警时: | ![]() |
低位或高位气体报警 低位报警触发: 用户可以现场选择,如果需要,将以上功能只在高位报警时触发。 LOW ALARM 或 HIGH ALARM 气体灯会闪亮,提示报警程度和受影响的传感器。这些功能可以在设置的报警水平触发。目前的设置可以随时查阅。 | ![]() |
传感器完整性报警
如果传感器丢失或传感器电缆损害,传感器完整性报警会触发。而且传感器1或2 FAIL 灯闪亮会指示哪个传感器或电缆发生问题。
低电源报警
电池容量随时显示,最长条表示完全电量。如果电池电量降低于可用水平,低电位报警启动报警信号,Arrow 在最短条以下,电池条闪烁。
传输状态
Rig Rat III 控制器和所有远程系统元件保持经常双向通讯。The radio transmitter (XMTR)
icon is continuously displayed on the detector to indicate system
communication status.
In the event of an alarm condition, the digitally
coded signal is transmitted to the appropriate
controller channel (and/or receiver alarm). The
XMTR icon changes and fl ashes to advise
transmission mode.
If the transmitter has been turned OFF to prevent false
alarms during calibration or service, the DISABLED icon will
appear below the XMTR icon. The disable button is located
in the operation bay.
In the event that communication is lost between the detector and
controller, or other system elements, the appropriate alarms will be
activated both at the controller and the remotely located detectors.
Detector Confi guration
The detector can be equipped with one or two remote gas sensor
heads in any gas combination desired. A simple rotary switch is used
to choose the sensor type and the measuring range for the sensor
head. Alarm setpoints can be fi eld-assigned to desired levels.
Security, Durability, Simplicity
Housed in a rugged, corrosion-resistant, 14 gauge stainless steel
enclosure, the tamper-proof, external hinged door is secured with a
key lock and high-tension latch, which protects the control bay. The
inner control door is equipped with slip hinges for easy access to
the setup and service bay. All electronics are sealed in weatherproof
enclosures - only the sensor is exposed to the environment.
Flexibility and Versatility - Building Block Approach
Modular Rig Rat III Systems are readily installed, modifi ed and
expanded without disturbing the work site.
Facility Monitoring
Any size of system is
possible. A system can
be readily expanded
and changed as site
requirements evolve.
Perimeter Monitoring
Rig Rat III provides a
cost-effective solution to
perimeter monitoring on
large sites.
Portable Monitoring
Field proven on mobile
work sites and by disaster
response teams, Rig Rat
III is the only truly portable,
independent, multi-point
system in the world.
Applications
Some common applications
include:
Drilling Rigs
Service Rigs
Offshore Platforms
Refi neries
Petrochemical Plants
Gas Plants
Perimeter Monitoring
Plant Turnarounds/Shutdowns
Pipelines
Tank Farms
Wellheads and Pump Jacks
Pulp and Paper Mills
Hazardous Waste Sites
Sewage Treatment Facilities
Loading Docks
Ammonia Plants
Nuclear Plants
Emergency Response Teams
Fire/HAZMAT R
Q P
Radio Signal - The Practical Solution
For optimal signal transmission and reception,
a variety of antennas are available.
The Rig Rat III stainless steel controllers are the central communication center
for the Rig Rat III gas detection system. The standard Rig Rat III controller allows
the simultaneous display of readings and alarm state messages for up to eight
remotely located sensors. The system uses a built-in digital 2.4 GHz, licensefree
ISM band (RF) transceiver, which allows two-way real-time communication
with system elements located up to 1.8 miles (3 km) away. The controller is in
constant communication with system elements. Detectors transmit a discretely
coded radio signal to the controller, advising the detector of a gas alarm or
integrity alarm condition.
Power Port:
Operate controller via line power, or connect
to external emergency power supply.
Battery backup with auto recharge.
Alphanumeric
Display: Real-time
readings for all detectors and
sensors.
Channel alarm LCD indicator
fl ashes and latches to
indicate alarm condition.
Each channel receives
unique digitally coded alarm
signals from the detector.
System Reset:
Alarm acknowledgement/
alarm reset switch
Security ON/OFF Keylock:
Protects access to operations bay
Rugged and Durable:
Rugged, stainless steel enclosure
Two Option Ports:
Two plug-in option ports:
one for alarm bar and one for
discrete relay option (future
expansion).
Audible:
Built-in audible (85 dB) and visual
alarms
Signal Transmission:
2.4 GHz digital, spread-spectrum, ISM
band RF transceiver with 1.8 mile (3 km)
transmission radius with 8 DBi antenna
Channel Activation:
Individual enable/disable
channel control switches
Security Locks:
Heavy duty stainless steel
latches.
Multi-Point Systems:
The system can be expanded to include up to several hundred individual
monitoring points. Larger systems require more than one controller.
RIG RAT III
Wireless Independent Receiver Controllers
with Remote Plug-in Options
Status LED:
Advises power status:
Green - A/C
Red - Battery
Optional:
Plug-in RS-485/MODBUS module
Increased Flexibility
Rig Rat III provides continuous monitoring
for combustibles (0-100 %LEL), oxygen
hazards and toxic gases.
Remote Sensors
Mix, match or change the gas type and/or
measuring range. Install one or two sensors as
desired. Confi guration is simple with plug-in, rugged
sensor units and simple rotary switch to change
type of sensor and range.
Remote Sensor Cables
Toxics and oxygen: 250 ft. / 76 m
Combustibles: 100 ft. / 30 m
Standard cable length is 10 ft. / 3 m. Optional
cables of up to 250 ft. / 76 m are available.
Continuous Power
Solar: Plug-in, stainless steel, solar panels allow
continuous operation in remote and isolated
locations. Available in 5, 10 and 20 watt versions to
accommodate system power requirements.
Line Power: 12 or 24 VDC direct or 110/230 VAC
trickle chargers power each detector at an adjacent
power supply, with short cable runs.
Independent Battery: Detector will operate on
batteries only for up to 30 days depending on
sensors and data transmission interval used.
Audible/Visual Alarms
Remote, plug-in audible/visual alarms alert
personnel that there is an alarm condition on site.
Alarms are powered by the controller or detector.
Optional receiver alarms are equipped with
their own RF transceiver with a 1.8 mile (3 km)
transmission radius. Receiver alarms include builtin
backup battery. Contact BW Technologies for
availability.
Relays
Plug-in, 10-amp SPDT AC/DC single and dual
relays trigger site-specifi c interfaces and
are powered by the controller or detector.
Solenoid Driver
Activates process or fl uid control systems, if required.
Datalogger
Data collected is expressed in % LEL, ppm or % by
volume, as required. IBM compatible.
Note: The detector is equipped with two option
ports. A 4-port MOB (multiple option box) is
available for the inclusion of additional interfaces.
Mounting Kits
Tripod and wall mount kits are available to simplify
installation. Tripod kits accept 5, 10 and 20 watt
solar panels.
Repeater Station
The repeater station effectively doubles the
transmission range of the detector. The repeater
station is equipped with both a radio receiver and
a transceiver that relays the alarm signal to the
controller. A solar panel will provide continuous
power. Contact BW Technologies for availability.
A wide range of rugged, versatile, plug-in options enable you to confi gure a system
to meet your specifi c monitoring needs. Add, change or move system components
as requirements evolve.
Maintenance-free combustible,
toxic and oxygen sensors
Remote Sensors
Select cable length:
up to 250 ft. / 76 m
10 Amp AC/DC Relays
Other
Mounting Kits
Weatherproof Explosion-proof
Solar-capable:
5, 10, 20 or 30 watt
120/230 VAC
line chargers
Power Choices
Independent 24 VDC Direct
battery power
Tripod 1 mount
Solenoid Driver
Controller Detector
60,000
candle power
160,000
candle power
101 dB siren 112 dB bullhorn
Controller Detector
High-output
audible
Alarm Bar
Discrete alarm relay
Wall mount
Datalogger
Remote Plug-In Accessories and Options
Audible/Visual Alarms
Remote
Receiver
Alarms
(Contact BW Technologies
for availability)
Tripod 2 mount
Repeater Station
s
Rig Rat III
Multi-Point Wireless
Gas Detection System
Gases Monitored: Change the gas
monitored and/or the measuring range at any time.
• Combustible Gases/Vapors
• Oxygen
• Toxics: Ammonia
Carbon Monoxide
Chlorine
Chlorine Dioxide
Ethanol
Ethylene Oxide
Hydrogen
Hydrogen Chloride
Hydrogen Cyanide
Hydrogen Sulfi de
Nitric Oxide
Nitrogen Dioxide
Ozone
Phosgene
Phosphine
Sulfur Dioxide
Power Independence: The following
sensor confi guration lists the duration of the
internal, rechargeable battery life (per charge):
• 2 toxic sensors: Up to 30 days
• 1 toxic, 1 LEL: Up to 5 days
• 2 LEL sensors: Up to 3 days
Note: Battery life will vary depending on
transmission interval and temperature.
Order Information
For full system order information and system
confi guration, contact BW Technologies.
RR-3000: Rig Rat III Wireless Gas Detector
(standard) comes with one 5 DBi antenna.
RR-3000S: Rig Rat III Non-Wireless Gas Detector
comes complete with all standard Rig Rat III
components, except antenna and transceiver.
RR-3C04: Rig Rat III 4-Channel Controllers are
capable of simultaneous display and annunciation
of up to 8 remotely located sensors.
RR-3CMBUS: RS-485/MODBUS output module.
RR-REP1-4: Rig Rat Repeater re-transmits
wireless signal from four (4) detectors to controller.
RR-3BAT-01: Optional 12 V, 10.4 amp hr.
battery pack.
RATINGS AND CERTIFICATIONS:
Locally distributed by:
BW1062-01-01-00-8.5x11-20050117-5379-4
RR-3000 Gas Detector:
SPECIFICATIONS
SYSTEM: Modular Multi-Point Wireless Gas Detection System
Signal Transmission: 2.4 GHz licence free, ISM band spread-spectrum RF transceiver.
User-settable discrete codes.
Distance: Up to 1.8 mi. / 3 km, depending upon antenna confi guration
GAS DETECTOR: Independent Rig Rat III detector with radio transceiver
Power: 12 volt, 3.4 amp hr. rechargeable battery
Battery Life: Up to 30 days, without active recharge (dependent on sensors)
Recharge: Via solar power; line (24 VDC direct, 110/230 VAC) or bench chargers
ALARMS: Clearly advises alarm levels both audibly and visually
Visual Alarms: Large, red fl ashing light
LCD: alarm level present, sensor affected and alarm type
Audible Alarm: Oscillating 85 dB at 3 ft. / 1 m (typical)
Gas Alarm Levels: Two per sensor (LOW, HIGH) with fi eld-settable setpoints
Other Alarms: Fault advises missing sensor, damaged cable and/or low battery alarm
LCD DISPLAYS: Two continuous, alphanumeric gas readouts and status displays:
Gas ppm or %: Simultaneously and continuously displays gas concentration(s) present
Status Indicators Advise: Transmitter status, battery level, sensor fault, alarm level setpoints
CONTROLS: Three:
1. Power ON/OFF
2. Transmitter (XMTR) DISABLE
3. Transmission TEST
PORTS: Two sensor ports; two option ports; charger port; TNC antenna port
SECURITY: Keylock access to control panel
GENERAL SPECIFICATIONS: 14 gauge stainless steel, NEMA 4, RFI/EMI shielded
Humidity: 5% to 95% RH (non-condensing)
Size: 8.46 x 11.26 x 4.53 in. / 21.49 x 28.6 x 11.51 cm
Weight: 11 lb. 6 oz. / 5.15 kg
GAS SENSORS: Remote interchangeable plug-in units
Type: Combustibles: catalytic bead; toxics and oxygen: electrochemical
Powered: By the detector
Humidity: 5% to 95% RH (non-condensing)
Temperature Range: Combustibles: -40 to +50 °C / -40 to +122 °F
Hydrogen Sulfi de: -40 to +50 °C / -40 to +122 °F
NH3, Cl2, HCl, ClO2, O3: -20 to +40 °C / -4 to +104 °F
Other toxics and oxygen: -20 to +50 °C / -4 to +122 °F
Physical: Toxic/O2: stainless steel, NEMA 4
Combustible: maintenance-free, encapsulated, NEMA 4
Warranty: 2 years, including all sensors (except NH3 and PH3- 1 year)
Gas Monitoring Specifi cations LCD
Increments
Standard Measuring Ranges Available
Units #=1 #=2 #=3 #=4 #=5 #=6
Combustibles (encapsulated) 1 % LEL % 0-100
Hydrogen Sulfi de 1 ppm ppm 0-100 0-50 0-500 0-20
Sulfur Dioxide 1 ppm ppm 0-100 0-20 0-10
Ammonia 1 ppm ppm 0-50 0-100
Carbon Monoxide 1 ppm ppm 0-500
Chlorine 0.1 ppm ppm 0-5.0 0-10.0
Oxygen 0.1% %v/v 0-25.0% 0-30.0%
Other Gases Contact BW Technologies
CONTROLLERS: Standard controller (RR-3C04) for up to 4 Rig Rat III detectors
Signal Output: MODBUS (RS-485) -optional
Signal Input: Discretely coded radio signals from each detector
Power: 110 VAC; 230 VAC (selectable)
Battery Backup: Two 12 VDC rechargeable batteries (normal operation: up to 4 hrs.)
ALARMS:
Visual: LCD displays alarm level present, sensor affected and alarm type
Audible: 85 dB at 3 ft. / 1 m (typical)
ALARM RELAY OUTPUTS: Four (4) SPDT relays; 10 amp @ 110 VAC/24 VDC, 8 amp @ 230 VAC
INDICATORS: LEDs (four / channel): 2 alarm indicators, 1 fault, 1 channel enable
CONTROLS: One ON/OFF switch; one ENABLE/DISABLE switch per channel and one
momentary reset/test switch
PORTS:
Antenna port: TNC (reverse polarity)
Alarm bar port: 12 VDC output per channel
External relay port: Alarm specific relay option
Common relay port: Low, high and fault (latching confi gurable)
Humidity: 5% to 95% RH (non-condensing)
Enclosure: Self-contained 14 gauge stainless steel with mounting fl anges, NEMA/Type 4
Physical: 14.95 x 11.16 x 5.15 in. / 37.97 x 28.35 x 13.08 cm; weight 21 lb. / 9.53 kg
DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Sensors: LEL: Class I, Div. 1, Groups C, D; Class II, Div. 1, Group G
Toxics, Oxygen: Class I, Div. 1, Groups C, D; Class II, Div. 1, Group G
Controller: n
for ordinary locations
n Class I, Div. 1, Groups C, D; Class II, Div. 1, Group G